The factory settles how the home is built. The planning conditions settle how big it can be, how tall, and how close to your boundary.

The Department of Housing's guidance says a home in a back garden can be built on site. It names standard methods such as blockwork or timber frame. It says that alternatively, prefabricated panels or modular buildings may be used. Irrespective of the method used, it says, the home must comply with Irish Building Regulations. The Department's guide sets out what these methods are meant to deliver. The planning conditions set the floor area, the height and the distances to a boundary. Read both before you order a unit.

The planning side comes from Statutory Instrument 340 of 2026. It covers placing a detached house in the rear garden of a main house. Citizens Information says such a home must have a floor area of between 32 and 45 square metres. Read the planning rules guide for all of the conditions.

The short version

  • The words: the Department gives prefabricated panels and modular buildings as examples of Modern Methods of Construction.
  • Speed: the Department says these methods can speed up delivery of construction projects by between 20% and 60%.
  • Durability: all key elements of a new home must have a service life in the order of 60 years.
  • On paper: a home built off site for assembly on site needs a certificate or compliance with an Irish Standard.
  • In the garden: the conditions set the floor area, the height and the distance to a boundary, and the guidance sets the window area.
  • Afterwards: it cannot be sold or subdivided separately from the main house, and the extension exemption cannot be used on it.

Is there a difference between a modular home and a prefab?

Prefab is short for prefabricated, and the Irish guidance treats both words as the same family of methods. The Department of Housing's note says a garden home can be built on site. It names standard methods such as blockwork or timber frame. Alternatively, it says, Modern Methods of Construction may be used. It gives prefabricated panels, such as walls or roof panels, and modular buildings as examples of those methods.

Modern Methods of Construction is the wider phrase. The Department calls it an industry term used to describe a range of manufacturing and innovative alternatives to traditional construction. It says the term covers offsite techniques such as mass production and factory assembly, as well as onsite innovations.

One line settles the standard. Whatever method is used, the Department's note says, one of these homes must comply with Irish Building Regulations.

What a factory-built home actually is

The Department describes two shapes of factory building for housing.

The first is a whole box. The Department describes volumetric housing units as three-dimensional units made in factories. They are then delivered to site, where they are installed. It says a single volumetric unit can be a small dwelling. The level of finish can vary from a basic structure to one with all services installed. The category comes with or without cladding. It also comes with or without internal fit-out such as kitchens or bathrooms.

The second is a flat pack of large pieces. The Department describes panelised components as flat panel units, such as panelised walls. They are made in factories and assembled on site. Those components can include walls, roof and floors, insulation and linings. They can be made from timber frame or light gauge steel frame. Precast concrete panels, structurally-insulated panels and cross laminated timber are also named.

Ask which of the two you are being quoted, and ask how it gets from the road to the back garden.

What the Department says you gain

The Department's guide names three gains.

Time is the first. The Department's guide says these methods can speed up the delivery of construction projects by between 20% and 60%. It says many of the processes happen offsite in factory conditions. There, factors such as bad weather do not disrupt delivery times.

Build quality is the second. The guide says factory-standard precision and consistency adds to the quality of structures. It says that means they will achieve their intended performance and durability requirements of 60 years.

Warmth is the third. The guide says these methods strengthen quality of construction, such as improving air-tightness in homes. It says that improves the energy performance of homes. For the energy standard a new home in the garden has to reach, read the energy and insulation guide.

On price, read the Department's wording closely. Its guide says these methods can reduce construction costs when they are combined with a steady supply of standardised designs. Get your own job priced in writing.

The certificate a factory system needs

There is one piece of paperwork to ask every supplier about.

Start with what the certificate is for. The Department's guide names a scheme called Agrement certification. It applies to products and processes which do not fall within the scope of existing construction standards. That is either because they are innovative, or because they deviate from established norms.

The guide names who does the checking. It says the National Standards Authority of Ireland assesses and specifies testing. Where appropriate, it issues those certificates. The certificate confirms that new building products, materials, techniques and equipment are safe and fit for purpose. That is in accordance with the Irish Building Regulations and with the terms of the certificate. The Authority's own page calls the service independent technical assessment and certification. It covers construction products and systems for their intended use in Ireland. It says the assessment can consider design, manufacture, installation, durability and performance.

For a garden home the Department's note is direct. It says Modern Methods of Construction should be certified by that scheme. Leitrim County Council puts the same point in terms of the work itself. When one of these homes is built off site for assembly on site, a certificate or compliance with an Irish Standard is required.

So ask for it by name, in writing, before you pay a deposit. The Department's note says a list of certified systems can be found by selecting Building Systems on the Authority's certification search page.

It has to be permanent, not parked

One planning condition is about how the home is built, rather than where it goes.

The planning conditions say the way the detached house is built must not be temporary in nature, such as a caravan or mobile home. Whether a particular factory-built unit meets that condition is a question for your planning authority. Put the unit you are being offered to them before you order it.

Two other rules point the same way. The Department's note says all key elements of a new home must have a service life in the order of 60 years. Part D of the Building Regulations requires that all works be carried out with proper materials. It also requires them to be carried out in a workmanlike manner. The note describes proper materials as materials fit for the use for which they are intended. They must also be fit for the conditions in which they are to be used.

If a mobile home is what you had in mind, read the mobile home guide instead.

The size and the height are fixed before it leaves the factory

Two numbers set the box a unit has to fit inside.

Floor area comes first. The conditions say the total area of such structures placed in the rear garden shall not be less than 32 square metres. It shall not exceed 45 square metres. Wicklow County Council has published the Department's clarification on that condition. It says the 45 square metre figure is measured as the total internal floor area of the structure. Citizens Information words the band as a floor area of between 32 and 45 square metres.

Height comes second, and the roof chooses it. The conditions cap the height at 4 metres with a tiled or slated pitched roof, or 3 metres in any other case. Citizens Information says the same thing. Up to 4 metres if you have a tiled or slated pitched roof. Up to 3 metres if you have a different roof.

Ask for the finished external height of the unit on its foundations. Check it against the cap that goes with its roof. For what goes underneath it, read the foundations guide.

Where it sits changes the walls and the windows

A factory picks a wall build-up and a window layout before it ever sees your garden. Check both against the distance to your boundary.

Start with the planning distance. The conditions say the structure shall be a distance of not less than 0.6 metres from any wall or party boundary. Citizens Information puts it as being at least 0.6 metres away from any wall or boundary.

The building rules then change at a different line. The Department's note says there are significant differences under 1.0 metre. That is where any wall sits less than 1.0 metre from the site boundary, or on it. Inside that metre, an external wall should be fire resisting from both sides. That means inside to out and outside to in, achieving 30 minutes fire resistance. Beyond that metre, the note says such a wall should be fire resisting from the inside only. It still has to achieve 30 minutes.

The same distance sets your window area. The note says the area of openings allowed in a wall facing a boundary depends on the distance to it. Openings means windows and doors. Its table sets out how much:

  • less than 1 metre: 1 square metre per window opening, separated from other windows by 4 metres of 30-minute fire resisting construction;
  • 1 metre or more and less than 2 metres: 5.6 square metres in total;
  • 2 metres or more and less than 3 metres: 12 square metres;
  • 3 metres or more and less than 4 metres: 18 square metres.

The table assumes that any wall holding such a window or door has a fire resistance of at least 30 minutes. The wall that faces your own house is measured the same way. The note says the area of openings permitted in a wall facing the existing dwelling depends on the distance to that dwelling.

So measure both gaps before you choose a model. Then read the boundary distances guide.

What you cannot do with it afterwards

Four of the planning conditions apply after the work is finished.

It cannot be sold on its own. The conditions say the home may only be lived in together with the main house, and cannot be sold or subdivided separately from it.

It cannot be extended later. Class 1 covers the extension of a house by the construction or erection of an extension to the rear of the house. As replaced in 2026, Class 1 says that exemption shall only be used on the principal house. It says it is not to be used on any additional detached house within the grounds of the principal house. So plan the space you need now.

It cannot be let out by the night. The conditions say the home may not be used for short term letting.

And there is a deadline. The conditions apply only to development that is commenced and completed during a period that ends on 31 December 2030. Citizens Information says the home must be built between 27 July 2026 and 31 December 2030.

A worked example: a semi-d in Swords with a narrow side passage

The planning conditions say a garden home may not be given a new vehicular or pedestrian access onto a road. They also say independent pedestrian or wheelchair access to the home must be provided. It has to be within the grounds of the main house. In the Swords example, that means the side passage.

That passage has a size in the guidance. The Department's note says the access route to the home should keep a clear width of at least 0.9 metres. It says the route should have a clear head height of 2.1 metres. Measure your side passage against the 0.9 metres, not against the 0.6 metre boundary distance.

Then there is what has to be left. The conditions say at least 25 square metres of private open space must be left for the people living in the house.

On a Swords semi-d, that is three measurements and one phone call. Pace the side passage at its narrowest point. Pace the gap to each boundary where the home would go. Pace what is left of the lawn. Then ring your planning authority with the numbers in your hand.

What to ask before you order

Put the same list to every supplier and get the answers in writing:

  • is this a whole unit or a set of panels, and how does it reach the back garden;
  • what is the certificate reference for the building system, or the Irish Standard it complies with;
  • what is the total internal floor area, and the finished height on the foundations;
  • what is the fire rating of the wall nearest the boundary, and the window area in it;
  • what is the service life quoted for the key parts.

None of it skips the building rules. The conditions say that for the avoidance of doubt, the relevant building control legislation applies. That means the Building Regulations, including fire safety, and the Building Control Regulations. The Department's guide says all new buildings must comply with those. It says all key elements of a new home must have a durability of at least 60 years. For materials and workmanship it points to Technical Guidance Document D 2013.

Two more conditions shape the job. There shall be no separate connection to utilities, including water or wastewater, so read the water, power and drainage guide. And a notification goes to the planning authority not less than 14 days before the works start.

If your own garden and your own unit are the question, get the answer in writing. Waterford City and County Council describes a section 5 declaration as a formal, written request to a local planning authority. It is made under the Planning and Development Act 2000. The council says it confirms whether a project requires full planning permission or is exempt. It costs €80, with a four-week decision time.

Questions people ask

The limits come from the planning conditions rather than the factory. Floor area is capped between 32 and 45 square metres. Height is capped at 4 metres with a tiled or slated pitched roof, or 3 metres in any other case. The home must sit at least 0.6 metres from any wall or boundary. It cannot be sold or subdivided separately from the main house. Class 1, the extension exemption, cannot be used on it. On the build side, the Department says Modern Methods of Construction should be certified. That scheme applies to products and processes which do not fall within the scope of existing construction standards.

The Irish guidance treats both as the same family of methods. The Department's note says a garden home can be built on site using standard methods such as blockwork or timber frame. It says that alternatively, Modern Methods of Construction such as prefabricated panels or modular buildings may be used. The practical difference is shape. A volumetric unit is a three-dimensional unit made in a factory and delivered to site. Panelised components are flat panels made in a factory and assembled on site. Ask which one you are being quoted, and how it reaches your garden.

The Department of Housing's guide to Modern Methods of Construction says these techniques can speed up the delivery of construction projects by between 20% and 60%. It says many of the construction processes happen offsite in factory conditions, where factors such as bad weather do not disrupt delivery times. Get your own programme in writing.

The Department's note on these homes says that for new homes, including new garden homes, all key elements must have a service life in the order of 60 years. Its guide on Modern Methods of Construction says factory-standard precision and consistency adds to the quality of structures. It says that means they will achieve their intended performance and durability requirements of 60 years.

The planning conditions say the way the detached house is built must not be temporary in nature, such as a caravan or mobile home. Put your own unit and your own site to your planning authority, or ask for a section 5 declaration, before you order anything.

Sources, all read 21 November 2026. Statutory Instrument 340 of 2026 and Statutory Instrument 338 of 2026 on irishstatutebook.ie. Citizens Information on planning permission. The Department of Housing, Local Government and Heritage's information note on auxiliary dwellings. Its Modern Methods of Construction Introductory Guide, prepared in July 2023 with the Department of Enterprise, Trade and Employment. The National Standards Authority of Ireland on Agrement certification. Leitrim County Council on exempted developments. Wicklow County Council's publication of the Department's clarification on floor area. Waterford City and County Council on section 5 declarations.

General information, not planning or legal advice: check your own site with your planning authority. How we check these guides.