Building regulations, foundations and services

What energy rating does a garden home need?

The energy part of the building rules applies to a home in your rear garden. The Building Energy Rating certificate follows a rule of its own.

The energy rules for a garden home sit in Part L of the Building Regulations, conservation of fuel and energy. The Department of Housing's note on auxiliary dwellings lists Part L among the Parts of the Building Regulations a garden home has to meet. It says to refer to Technical Guidance Document L, 2022 on how to comply with Part L. The note also says a BER certificate is not required for a standalone building with a total useful floor area of less than 50 square metres.

There are two questions here. Take them one at a time. The standard the building has to reach comes first. The certificate comes after. Keep your supplier's quote beside you and tick off each figure below. Then go back to them about anything the quote does not answer.

Which energy rules apply to a garden home?

Part L, and two things put it there. Auxiliary dwelling is the Department's own name for a home like this. Its note says Statutory Instrument 340 of 2026 provides an exemption from planning permission for a detached auxiliary dwelling to the rear of a house, subject to certain conditions. One of those conditions says the relevant building control legislation shall apply, such as Building Regulations, including fire safety, and Building Control Regulations.

The note is direct about it. Irrespective of the exemption from planning permission, an auxiliary dwelling must comply with Building Regulations and Building Control Regulations. The note says Building Regulations set minimum performance requirements for buildings, including dwellings. It says they apply to the design and construction of an auxiliary dwelling in the same manner as they apply to new dwellings.

For Part L the note points you at one document. Here is what that document is. The Department says Technical Guidance Documents are published to accompany each part of the Building Regulations. They indicate how the requirements of that part can be achieved in practice. The Department says adherence to the approach a Technical Guidance Document outlines is regarded as evidence of compliance.

What a nearly zero energy dwelling (NZEB) has to reach

Two figures decide it. Both come from Technical Guidance Document L, 2022. It says the maximum permitted energy performance coefficient for a nearly zero energy dwelling is 0.30. It says the maximum permitted carbon performance coefficient is 0.35.

Both figures come out of software. The guidance says energy use and carbon dioxide emissions are calculated using the Dwelling Energy Assessment Procedure, or DEAP. The Sustainable Energy Authority of Ireland publishes it. The guidance says DEAP will calculate both of those coefficients for the dwelling being assessed. It says DEAP will clearly indicate whether compliance has been achieved.

How much of the energy has to come from renewables

The guidance puts it at a fifth. It says the nearly zero or very low amount of energy required should be covered to a very significant extent by energy from renewable sources. It says that includes energy from renewable sources produced on-site or nearby.

Then it puts a number on that phrase. A Renewable Energy Ratio of 0.20 represents a very significant level of energy provision from renewable energy technologies. A Renewable Energy Ratio of 0.2 represents 20 per cent of the primary energy from renewable energy technologies to total primary energy.

So ask which technology your design uses to get there. Ask what figure the assessment came back with, and get that in writing.

The U-values the walls, roof, floor and windows have to meet

Insulation is next, element by element, roof to floor. The guidance specifies acceptable levels of thermal insulation as an average area-weighted U-value for each fabric element type. Column 2 of its Table 1 holds those figures.

Part of the buildingArea-weighted average U-value (W/m2K)
Pitched roof, insulation at ceiling0.16
Pitched roof, insulation on slope0.16
Flat roof0.20
Walls0.18
Ground floors0.18
Other exposed floors0.18
External doors, windows and rooflights1.4

A note to that table says windows, doors and rooflights should have a maximum U-value of 1.4 W/m2K. The guidance allows those values to be relaxed for individual elements or parts of elements, where considered necessary for design or construction reasons. The maximum values it gives there are 0.3 for roofs, 0.6 for walls, 0.6 for ground floors and 3.0 for external doors, windows and rooflights. Where the source of space heating is underfloor heating, the maximum floor U-value should be 0.15 W/m2K.

Hold that column against the quote you were sent. Where a figure in the quote is higher than the one here, ask why. Ask before you sign anything. Keep the answer.

Does a garden home need a BER certificate?

The certificate rule has its own Regulations. The Department's note gives those as Statutory Instrument 243 of 2012, the European Union (Energy Performance of Buildings) Regulations 2012. Article 4 states that they do not apply to a stand alone building with a total useful floor area of less than 50 square metres.

Citizens Information puts it to homeowners like this. It says some buildings do not need a BER certificate when they are sold or rented. It says these are called BER exempt. The list includes stand-alone buildings with floor space of less than 50 square metres.

Citizens Information also gives the size of a home built under this exemption. The detached home must have a floor area of between 32 and 45 square metres. It must be built between 27 July 2026 and 31 December 2030. Hold your own floor area up against the 50 square metres. Then put the question to your building control authority. Do it in writing.

The BER scale changed on 24 May 2026

Take the letters as they stand today. Citizens Information says a Building Energy Rating evaluates your home based on how energy efficient it is. The ratings are A0, A, B, C, D, E, F and G. A0 is the highest rating and G is the lowest. A0-rated homes are the most energy efficient and do not use fossil fuels. If your home has a gas boiler, it cannot get an A0 rating.

Before that, BER certificates used a different scale with 15 ratings. The old scale had sub-categories such as B1 and C2. On 24 May 2026 it was changed to bring Ireland's BER rating system in line with what is used in other EU countries. SEAI says all sub-categories such as B1, B2 and B3 will be removed. It says the change cuts the number of rating levels from 15 to a more user-friendly 8. Certificates are valid for 10 years from the date they were issued.

So if a brochure quotes you a rating like A2 or B1, ask which scale that came off.

What to get in writing before you order

Four questions, all with a paper answer. Ask them before you order:

  • Which U-values are the walls, roof, floor, windows and doors built to?
  • Who runs the DEAP calculation, and what coefficients does it return?
  • Which renewable energy technology does the design use to reach the ratio?
  • What does your building control authority say about the certificate for your own floor area?

Read the building regulations guide next for the other parts of the Building Regulations the home has to meet. For what goes in under the floor, read the foundations guide.

Questions people ask

gov.ie says the home energy grants scheme is open to all owners of dwellings built prior to 2006. It says homes built prior to 2011 are eligible for the heat pumps and solar thermal and solar PV measures. Check those dates against your own build before you budget for a grant.

Technical Guidance Document L, 2022 says renewable energy technologies means technology, products or equipment that supply energy derived from renewable energy sources. The examples it gives are solar thermal systems, solar photovoltaic systems, biomass systems, systems using biofuels, heat pumps and other small scale renewable systems. Ask your supplier which one the design uses.

Citizens Information says you get a BER for your property by hiring an independent assessor registered with the SEAI to complete a BER assessment.

Sources, all read on the day this guide was published. Technical Guidance Document L, Conservation of Fuel and Energy, Dwellings, 2022. The Technical Guidance Documents collection on gov.ie. The Department of Housing's information note on auxiliary dwellings. Statutory Instrument 243 of 2012 and Statutory Instrument 340 of 2026 on irishstatutebook.ie. Citizens Information on Building Energy Ratings and on planning permission. SEAI on the simplified BER scale. gov.ie on home energy grants.

General information, not planning or legal advice: check your own site with your planning authority. How we check these guides.

Thinking about a garden home?

Get a free, no-obligation quote for a garden home in your back garden. Whether a garden home suits your site depends on the Class 3A conditions, so check them for your own property.

Get a FREE Quote

More on building regulations, foundations and services

Building regulations, foundations, energy performance and how water, power and wastewater connect to the main house.

Every topic