Planning rules

How close to a boundary can a garden home go in Ireland?

These are the distances that decide where a garden home can stand, from the planning minimum to the fire line that changes how the walls are built.

A garden home has to stand at least 0.6 metres from a boundary. Once a wall of it is less than 1 metre from a boundary, how that wall has to be built changes too. The two distances come from different rules, so this page takes them in turn.

Class 3A is the planning rule that lets a detached house go into a rear garden without planning permission, as long as every condition set for it is met. A principal house is the house whose rear garden the new home goes into.

Class 3A covers "the construction, erection or placing of a detached house in the rear garden of a principal house". It was added to the Planning and Development Regulations 2001 by S.I. No. 340 of 2026, and it came into operation on 27 July 2026.

The 0.6 metres is one of its conditions. Condition 14 says the structure "shall be a distance of not less than 0.6 metres from any wall or party boundary". Condition 15 applies the same 0.6 metres to any window and the boundary it faces.

That is the planning minimum. A second set of distances then decides how the walls, the windows and the roof have to be built, and those rules use a different name for the same building.

An auxiliary dwelling is what the Department of Housing, Local Government and Heritage calls a detached home built to the rear of the original house. Its information note on auxiliary dwellings says that the closer the accommodation is to a property boundary, the higher the fire safety requirements for the building's walls.

The distances, at a glance

  • 0.6 metres: the least the structure may sit from any wall or boundary, under condition 14. Condition 15 asks the same of a window from the boundary it faces.
  • 1 metre: the information note says there are significant differences where any wall is located less than 1.0 m from the site boundary, or on a site boundary.
  • Window and door openings: under 1 m from the boundary, the cap is 1 m² per window opening, and each one should be separated from other windows by 4 m of 30-minute fire resisting construction. From 1 m up to 2 m, the cap is 5.6 m² of opening in total.
  • Your own house: for separation between an auxiliary dwelling and the nearest external wall of the main building, and vice-versa, those distances should be doubled.
  • 6 metres: a roof this close to a boundary needs a rating for how well it resists fire spreading over its surface. Within 6 metres it should achieve BROOF (t4) (European) or AA (National).
  • 25 square metres: private open space is the outdoor space kept for the people in the house alone, and at least this much of it must still be left.

How close to the boundary can it go?

Not less than 0.6 metres. Exempted development is work that does not need planning permission, and each kind of it comes with a list of conditions you have to meet.

Condition 14 applies to any wall or boundary. So take that distance on each side of the garden, not only at the end. A garden with a block wall on one side, a fence on the other and a hedge line at the back gives you three figures. Write all three down and work from the tightest.

Across the width of a garden with a boundary on each side, the 0.6 metres comes off twice. Give each side its 0.6 metres and a garden 7 metres wide is down to 5.8 metres of width you can build on. That is before any of the fire distances below touch it.

What changes inside 1 metre of the boundary

The walls change, and so does the glass you can put in them. The information note is the Department's guidance on how the Building Regulations apply to an auxiliary dwelling. It says there are significant differences where any wall of the auxiliary dwelling is located less than 1.0 m from the site boundary, or on a site boundary. Building Regulations apply to the design and construction of an auxiliary dwelling in the same manner as they apply to new dwellings.

Say a wall sits less than 1.0 m from the boundary. That wall should be fire resisting from both sides, from inside to out and from outside to in. It should achieve 30 minutes fire resistance, in accordance with I.S. EN 13501-2. The outermost face of the external walls should then be built of materials with a reaction to fire classification of Class B or better.

Move the same wall out past 1.0 m and it should be fire resisting from the inside only, again achieving 30 minutes fire resistance. The outermost face should be Class C or better.

These higher requirements are there to protect the occupants from a fire in another building which may be close by, whether at the time of construction or in the future. So ask your supplier, in writing, what fire resistance each wall achieves and how its outer face is rated. Give them the distance from that wall to the boundary when you ask.

How much window and door area each distance allows

Table 1 of the information note caps how much of a wall facing a boundary can be window and door opening. An unprotected area is the total area of the window and door openings in a wall, including their frames. As distance increases, that open area may also increase. The table assumes the wall a window or door sits in has a fire resistance of at least 30 minutes. The distance is measured from the garden auxiliary dwelling to a site boundary.

  • Less than 1 m: 1 m² per window opening, which should be separated from other windows by 4 m of 30-minute fire resisting construction.
  • Equal to or greater than 1 m and less than 2 m: 5.6 m² total unprotected area.
  • Equal to or greater than 2 m and less than 3 m: 12 m² total unprotected area.
  • Equal to or greater than 3 m and less than 4 m: 18 m² total unprotected area.

So measure the opening rather than the pane. Note 4 sends you further for anything the table does not cover. For any distances greater than those set out, or for any site-specific complications, the designer should refer to Technical Guidance Document B 2017, Section 4.5.

Hold that against the elevation you have been shown. A wall sitting at the 0.6 metre minimum is in the first row. Read the opening area drawn on that elevation against it before you price a home at the top of the size range.

The gap to your own house is measured differently

Double it. Note 2 to Table 1 says that for separation between an auxiliary dwelling and the nearest external wall of the main building, and vice-versa, distances should be doubled. The note's reason is that a fire in one building should not pose a risk to the other on the same site.

So a wall facing your own house is read at twice the distance you measured. Pace the gap between the back of the house and the face of the garden home, then look up the table at double that figure. The wall of the house looking back at it is read the same way.

Roofs within 6 metres of a boundary

A roof which adequately resists a spread of fire over its surface, and penetration of fire into its structure, can protect occupants if a nearby building is on fire. BROOF (t4) (European) and AA (National) are the ratings for that, and any roof located within 6 metres of a boundary should achieve one of them. The note says roofs can present a risk to fire spread, particularly where a building is located in a built-up area. As with external walls, the closer the roof is to a boundary, the higher the requirement.

Measure 6 metres in from each boundary and see whether any part of the roof falls inside that line. Where it does, put the classification on the specification you ask a supplier to quote against.

The path to the door needs width of its own

The note also asks for a way in on foot, and that route has measurements of its own. Curtilage is the land that goes with your house, together with any outbuildings standing on it. The path to the door has to run inside that land.

Condition 11 says the detached house needs its own way in on foot or by wheelchair, provided within the curtilage of the principal house. The information note calls that an external access route independent of the main dwelling, usually via a side pathway or mews lane. It is there for escape in case of fire from both dwellings, and for access for firefighting. Fire brigade appliances should be able to get within 45 m of the principal entrance to the auxiliary dwelling.

That route starts at the entrance at the boundary of the ground the home stands on. It can also start at the point where a visitor would normally alight from a vehicle on that ground. Along it, the route should keep a clear width of at least 0.9 m and a clear head height of 2.1 m.

Put condition 14's 0.6 metres and the route's 0.9 m clear width side by side on your own plan. Then walk both sides of the house with a tape before you decide which way the path runs and which way the building shifts.

What else in the garden fixes the position

Three more things in the garden decide where it can sit.

Start with private open space. Condition 9 says the structure shall not cut the private open space reserved exclusively for the occupants of the house below 25 square metres. Pace out what would be left for the house with the garden home and the path to its door both in place. Hold that against the 25 square metres.

Then look at the septic tank and the pipes that drain it. The Environmental Protection Agency says septic tanks and other domestic waste water treatment systems are used by rural home owners to treat waste water from their homes. A percolation area is the network of shallow underground pipes that carries the liquid out of a septic tank and releases it into the soil.

The information note says an auxiliary dwelling should not be built on or close to an existing septic tank or percolation area or access points to drainage infrastructure. Condition 13 says that in the case of non-piped waste water treatment, the structure shall not encroach on any approved percolation area.

On a bungalow in Mayo with a tank in the garden, dig out the drawings for the system before you pick a corner.

Fuel tanks carry distances of their own. Where there is no existing oil tank within 1.8 m of the new auxiliary dwelling, no additional provisions apply. Any external wall or eaves closer than 1.8 m to such a tank should have 30 minutes fire resistance from the outside. The dwelling should not have any window or door openings within 1.8 m of an oil storage tank. LPG works the same way. Where there is no existing LPG tank within 3 m, no additional provisions apply. Table 2 of the note sizes a tank by its water capacity in litres. Without a fire wall it sets 2.5 m for a tank of 150 to 500 litres, and 3 m for one of 501 to 2,500 litres.

A worked example: a semi-d in Swords

Take a rear garden 7 metres wide, with a block wall to one neighbour and a fence to the other. The home on the drawing is 5 metres wide, which leaves 2 metres to share between the two sides.

Push it over so one wall sits at 0.6 metres and the other at 1.4 metres. The two walls now land in different rows of the table. The 0.6 metre wall is under 1 m. It should be fire resisting from both sides to 30 minutes, with its outer face Class B or better. Its windows are capped at 1 m² each, separated by 4 m of 30-minute fire resisting construction. The 1.4 metre wall is in the row from 1 m up to 2 m. It is fire resisting from the inside only, Class C or better on the outer face, with 5.6 m² of total unprotected area to spend.

Centre the same building instead and both walls sit at 1 metre. That puts both of them in the row from 1 m up to 2 m. Decide which wall you want the glass on, then set the distances to suit it. Remember the side passage has the 0.9 m clear width to answer as well.

If you are not sure, ask the council

Section 5 of the Planning and Development Act 2000 gives you a route to a written answer. A question may arise about what "is or is not exempted development within the meaning of this Act". Any person may then "request in writing from the relevant planning authority a declaration on that question", on payment of the prescribed fee. The authority shall issue the declaration "within 4 weeks of the receipt of the request".

Dublin City Council's section 5 application form asks for two copies of an OS map at a scale of 1:1000, with the site clearly outlined in red. The fee on that form is €80.00. Look up the figure your own council publishes. Then ask the question with your own measured distances marked on the map.

That declaration is separate from the notice Class 3A asks for. Condition 16 wants a notification to the relevant planning authority not less than 14 days prior to the commencement of the works. It informs them of the intention to use this class of exemption. It also confirms that the site meets the requirements, and states the reason for the intended use.

What to measure before you order

  1. The distance from each wall of the home to the nearest wall or boundary, against the 0.6 metres in condition 14.
  2. Which side of the 1.0 m line each of those walls falls on, because that sets the fire resistance and the reaction to fire classification for that wall.
  3. The window and door opening area planned in each wall, against the row of Table 1 that its distance puts it in.
  4. The gap between the garden home and the nearest external wall of the house, doubled before you read the table.
  5. Whether any part of the roof sits within 6 metres of a boundary.
  6. The clear width of the side passage you intend to use for access, against the 0.9 m the route asks for.
  7. The private open space left for the house once the home and its path are in, against the 25 square metres.
  8. The position of any septic tank, percolation area, oil tank or LPG tank already in the garden.

Questions people ask

No. Condition 14 of Class 3A puts the structure at a distance of not less than 0.6 metres from any wall or boundary. A home placed on the boundary falls outside the class. The information note also names a wall on a site boundary as the point where the fire safety requirements are at their highest.

It falls outside the class, and you need planning permission if you are going to build a house. Development of a class specified in column 1 of Part 1 of Schedule 2 is exempted development provided that it complies with the conditions and limitations specified in column 2 opposite that class. The 0.6 metres is one of those conditions. Citizens Information warns that it is an offence to do work that requires planning permission without having planning permission, and that this offence can carry very large fines and possible imprisonment.

Not in practice. Condition 7 counts the garden home together with any other such structures previously constructed, erected or placed under Class 3 within the curtilage. That total must not exceed 45 square metres, and the home itself must be not less than 32 square metres. The Department of Housing, Local Government and Heritage clarified on 6 November 2026 that this reference to Class 3 means Class 3A only, so the 45 square metre limit is not reduced by a shed, garage or greenhouse already in the garden. A shed still uses up garden, and at least 25 square metres of free garden space has to be left.

Sources: S.I. No. 340 of 2026 (Class 3A) and section 5 of the Planning and Development Act 2000, on irishstatutebook.ie. Also the Department of Housing, Local Government and Heritage information note on auxiliary dwellings, 1st edition July 2026, Citizens Information and Dublin City Council. All read 2 November 2026.

General information, not planning or legal advice: check your own site with your planning authority. How we check these guides.

Thinking about a garden home?

Get a free, no-obligation quote for a garden home in your back garden. Whether a garden home suits your site depends on the Class 3A conditions, so check them for your own property.

Get a FREE Quote

More on planning rules and the exemption

What the Class 3A exemption for detached garden homes allows, the conditions you must meet, and when you still need planning permission.

Every topic